PT on / off:

The current functionality of PT On / Off is only available from vs | plus version 6.2.5. It should not be used in older versions of vs | plus.

Whether a traffic stream reacts to the OCIT commands or not can be set in the flags. Individual settings can be made for each traffic stream in the "PT on/off" column. (Read more)


Display

Identifier

Values

Description

PT on/off

PT, IT in dependence of modification control


In OCIT-O and OCIT-I it is possible to set additional influences (modifications) in each signal program. 

PT Influence on / off IT Influence on / off.





INAC

This traffic stream does not respect the OCIT commands.


PToff

This TS is no longer active with PT off.


IToff

This TS is no longer active at IT off.


PToffOrIToff

This TS is no longer active with PT or IT off.


PToffANDIToff

This TS is no longer active with PT and IT off.

Sonder

Special intervention on/off


The OCIT function Z-special intervention can be switched on and off record-dependently for each traffic stream. The special intervention (Sonder) identifier must be set to "On" for the intervention to take effect.





Off

Special intervention inactive.


On

Special intervention active.


Parameter

from vs | plus version

Comment

PT on/off

6.2.5

The current functionality of PT On/Off is only offered from vs | plus version 6.2.5. It should not be used in older versions of vs | plus.

Special intervention

6.2.6

Is only active from this version of vs | plus.