In order for the traffic stream to receive information about the traffic from the road, it must be linked to detectors or message points. This is done by assigning the logical vs | plus detectors to a traffic stream. Several logical inputs can be assigned to a traffic stream. Depending on whether it is a detector or message point, additional parameters can be set.


 vs | studio




Input (logical)



Description

Names of the logical inputs. Read only.



Range of values

List of defined Inputs.



vs | plus version

All




Traffic stream



Description

Each detector / message point must be assigned to a traffic stream. In PT and IT, a detector can be assigned to several traffic streams with different properties. 



Range of values

List of defined traffic streams.



vs | plus version

All




Position



Description

Sequence in which the detectors / message points are traversed. This sequence is specified with the overrun position of a message point or detector. Must be set for message points (PT traffic streams). For IT detectors, the order is determined by vs | plus.



Range of values

1 .. 14



vs | plus version

All




Counting point



Description

Used for open vs | plus. It can be defined whether a detector should be used for counting vehicles or not.



Range of values

  • 🗹  used as a counting point.
  • 🞏  not used.


vs | plus version

from 6.2.5




AMLi-entry



Description

For message points that affect multiple traffic streams, an entry is made in the PT memory. This entry can be locked if it is not desired. If the logout is locked, no forced counting is entered either. For parameter groups without logoff, the forced count is only entered if a pseudo logoff point is parametrized, and the entry is not locked.



Range of values

  • 🗹  the message point is entered into the PT archive.
  • 🞏  will not be entered.


vs | plus version

All




Detector Type



Description

Is derived from the assigned traffic stream. Read only:



Range of values

  • IT
  • PT 
  • PT memory


vs | plus version

All




Input (physical)



Description

List of input assignments. Read only.



Range of values

List of the control unit’s inputs. Basic Data -> Inputs -> Parallel inputs; Basic Data -> Inputs -> Serial inputs. Read only



vs | plus version

All





 vs | workSuite




Display

Identifier

Values

Description



TS

Assignment to traffic stream


Each detector/message point must be assigned to a traffic stream. In PT and IT, a detector can be assigned to several traffic streams with different properties. 











List

All traffic streams. 



Position

Detector position in sequence


Sequence in which the detectors/message points are traversed. This sequence is specified with the overrun position of a message point or detector. Must be set for message points (PT traffic streams). For IT detectors, the order of vs | plus is set.











1 .. 14




Distance

Distance to stop line


Defines the distance of the detector to the hold bar but is currently not used in vs | plus.






Counting point



Counting point (Zählstelle)

Counting point


Used for open vs | plus. It can be defined whether a detector should be used for counting vehicles or not.











yes (ja)

Used as a counting point.





no (nein)

Not used.



Lane

Lane


Currently not used in vs | plus.









Call_mode

Request mode


The storage of requests by the PT module in the actual PT memory is possible both for radio telegrams and for conventional detector requests. The request type is used to specify whether a request is made serially with telegram or in parallel via the normal detector inputs.











Parallel

The message point is parallel.





Serial

The message point is serial.





VA Bearbeitung

The message point is sent via open vs | plus.



Entry

Entry in PT memory


For message points that affect multiple traffic streams, an entry is made in the PT memory. This entry can be locked if it is not desired. If the logout is locked, no forced counting is entered either. For parameter groups without logoff, the forced count is only entered if a pseudo logoff point is parametrized, and the entry is not locked.











Entry yes

The message point is entered into the PT archive.





Entry no

Will not be entered.






Parameter

from vs | plus version

Comment



Counting point

6.2.5

Is available only from this version. In the previous version lanes.