Defining the global control strategy.
Display |
Identifier |
Values |
Description |
Name |
Name of the signal program |
|
PRG No. and names are taken from the supply of the control unit and cannot be changed. |
|
|
|
|
|
|
List |
All signal programs from the basic supply. |
PRIN_MaS |
Principle definition for main series |
|
This defines the principle according to which the stage control main series is to be made. |
|
|
|
|
|
|
ProcCycl |
Cyclic processing of the main series. |
|
|
Acyclic processing of the main series. |
|
|
|
FIXTIME |
Fixed time control: assigned fixed time program is active. |
|
|
Cyclic processing of the main and minor series by priority element. |
|
|
|
Step_w/o_cancel |
Step control without stage return. |
|
|
Step_with_cancel |
Step control with stage return. |
|
|
StgCtrl_noBack |
Phase control without stage return. |
|
|
StgCtrl_wiBack |
Phase control with stage return. |
PRIN_MiS |
Principle definition for minor series |
|
This defines the principle according to which the stage control minor series is to be compiled. |
|
|
|
|
|
|
MiSwCall |
The stage control takes into account the minor series according to the table "Minor streams with call" (default). |
|
|
The stage control takes into account the minor series according to the table "Minor series same as main series". |
|
GFSFP |
Signal frame plan |
|
Definition of whether it is a fully traffic-based program or one with a signal frame plan. |
|
|
|
|
|
|
accSFP |
By signal frame plan. |
|
|
FTA |