Display

Identifier

Values

Description

Det

Control unit detector


When the set values are reached, a message is output, or the defined reaction is triggered. 







List

All parallel detectors of the basic supply. 

Occupancy: Threshold 1

Occupancy time for threshold 1


Sending a message to the control unit (vs | plus error message 20) after threshold 1 has been reached.







0 .. 3200

Time in seconds

Occupancy: Threshold 2

Occupancy time for threshold 2


After reaching threshold 2, the defined reaction is triggered. 







0 .. 3200

Time in seconds

Reaction

Reaction


Reaction to reaching threshold 2







Cancel




Controller in cyclic mode




Send message

See vs | plus error message



Switch off whole controller




Switch off partial intersection 1




Switch off partial intersection 2




Switch off partial intersection 3




Switch program according to YAUT




Switch to pre-configured emergency program




Reset vs | plus

See plausibility general data.

Gap: Threshold 1

Threshold 1 for gap


Sending a message to the control unit (vs | plus error message 21) after threshold 1 has been reached.







0 .. 3200

Time in seconds

Gap: Threshold 2

Threshold 2 for gap


After reaching threshold 2, the defined reaction is triggered. .







0 .. 3200

Time in seconds

Reaction

Reaction


Reaction to reaching threshold 2







Cancel




Controller in cyclic mode




Send message

See vs | plus error message



Switch off whole controller




Switch off partial intersection 1




Switch off partial intersection 2




Switch off partial intersection 3




Switch program according to YAUT




Switch to pre-configured emergency program




Reset vs | plus

See plausibility general data.