13

serious error

Supply with VCB

The VCB file is faulty. Test not passed!

1

Error code: 

2 - The intersection number does not match 

3 - Signal groups that do not exist in the device are addressed 

4 - Detectors that do not exist in the device are addressed 

5 - The file could not be opened 

6 - It is not a `VCB' file 

7 - File version does not match vs | plus version 

8 - Error in parameter file 

9 - Errors in the data structure 

10 - Error in parameter set 

11 - Invalid parameter values 

99 - Global data structure not available 

2

Error code message no. 1 is

Message parameters 2

2, 3, 4, 7

Expected value

6

0: VCB file

1: Multi-VCB file

9

vs | plus group number

11

Value read

3

Error code message no. 1 is

Message parameters 3

2, 4, 7

Value read

6

1: surplus vs | plus supply

2: surplus open vs | plus supply

3: Multi-VCB not recognised

9

vs | plus object number

11

Hi-word of the parameter ID

4

Error code message no. 1 is

Message parameters 4

7

0: wrong vs | plus version

1: wrong open vs | plus version

9

Error detail (*)

10

Programme number

11

Lo-word of the parameter ID


(*) Error detail number

Meaning

1

Invalid symbol / character

2

Invalid value

4

Invalid number of elements

8

ID in invalid range

16

Unaddressed traffic stream conflict

32

Check rows, columns


Please refer to the table for the assignment of vs | plus group and object numbers vs | plus group and object numbers.