Group no. |
Object no. |
Type |
Class |
Description |
1 |
1 |
Topology |
Display element |
Definitions of display elements |
1 |
2 |
Topology |
Traffic stream |
Definitions IT, PT standard, PT module traffic streams |
1 |
3 |
Topology |
Input |
Definitions IT, Standard PT, PT Module Detectors |
1 |
4 |
Topology |
Priority element |
Definitions of priority elements |
1 |
91 |
Topology |
Priority element |
Definitions of priority elements |
1 |
5 |
open vs | plus |
FreeStyle Parameters |
Free parameters |
1 |
6 |
vs | plus |
vs | plus version |
vs | plus internal information |
1 |
95 |
Topology |
Display element |
Assigned partial node does not exist |
2 |
7 |
Data set |
vs | plus Programme definition |
Programme definitions |
2 |
41 |
Data set |
vs | plus Programme definition |
Frame plan definitions |
2 |
86 |
Data set |
vs | plus Programme definition |
Extended frame plan definitions |
3 |
8 |
Parameters |
Detector |
Individual traffic |
3 |
9 |
Parameters |
Detector |
Standard PT |
3 |
10 |
Parameters |
Detector |
PT module |
4 |
11 |
Parameters |
Traffic stream |
Times |
4 |
12 |
Parameters |
Traffic stream |
Flags |
4 |
13 |
Parameters |
Traffic stream |
Parallel extension |
4 |
14 |
Parameters |
Traffic stream |
Locking |
4 |
15 |
Parameters |
Traffic stream |
Forwarding |
4 |
16 |
Parameters |
Traffic stream |
Lead |
4 |
17 |
Parameters |
Traffic stream |
Lag |
4 |
18 |
Parameters |
Traffic stream |
Hold back |
4 |
19 |
Parameters |
Traffic stream |
PT criteria sequence (standard PT, PT module) |
4 |
20 |
Parameters |
Traffic stream |
Standard PT |
4 |
21 |
Parameters |
Traffic stream |
Conflict matrices |
4 |
22 |
Parameters |
Traffic stream |
PT module |
4 |
23 |
Parameters |
Frame signal plan |
Frame signal plan |
5 |
24 |
Parameters |
Stage Rank-dependent |
Stage control (3 classes) |
5 |
25 |
Parameters |
Stage Rank-dependent |
Main series class 1 |
5 |
26 |
Parameters |
Stage Rank-dependent |
Main series class 2 |
5 |
27 |
Parameters |
Stage Rank-dependent |
Main series class 3 |
5 |
28 |
Parameters |
Stage Rank-dependent |
MBB |
5 |
90 |
Parameters |
Stage Rank-dependent |
Stage control (12 classes) |
5 |
92 |
Parameters |
Stage Rank-dependent |
Main series all classes |
6 |
29 |
Parameters |
Stage traffic stream dependent |
Minor series as main series |
6 |
30 |
Parameters |
Stage traffic stream dependent |
Required minor streams |
6 |
31 |
Parameters |
Stage traffic stream dependent |
Minor streams without call |
6 |
32 |
Parameters |
Stage transition |
Left turn arrow |
7 |
38 |
Parameters |
Stage transition |
Intergreen time matrix (traffic-dependent) |
7 |
33 |
Parameters |
Stage transition |
Intergreen time matrix (shortened) |
7 |
34 |
Parameters |
Stage transition |
Begin offset time matrices (traffic-dependent) |
7 |
35 |
Parameters |
Stage transition |
End offset time matrices (traffic-dependent) |
8 |
36 |
Parameters |
Traffic stream |
PT route |
8 |
37 |
Parameters |
Traffic stream |
PT message point |
4 |
39 |
Parameters |
Traffic stream |
Logical detector link |
4 |
40 |
Parameters |
Traffic stream |
Logical traffic stream link |
10 |
57 |
Parameters |
Plausibility |
General |
10 |
58 |
Parameters |
Plausibility |
Control unit detectors |
10 |
60 |
Parameters |
Plausibility |
Traffic streams |
10 |
59 |
Parameters |
Plausibility |
vs | plus Detectors |
9 |
42 |
Adaptive control |
Traffic-dependent modification |
Intervention Information |
9 |
43 |
Adaptive control |
Traffic-dependent modification |
Intervention Frame plan |
9 |
44 |
Adaptive control |
Traffic-dependent modification |
Incompatibility binary |
9 |
45 |
Adaptive control |
Traffic-dependent modification |
Ternary incompatibility |
9 |
56 |
Adaptive control |
Traffic-dependent modification |
Incompatibility Max. Red |
9 |
84 |
Adaptive control |
Traffic-dependent modification |
Intervention definition |
9 |
85 |
Adaptive control |
Traffic-dependent modification |
Intervention frame plan |
9 |
87 |
Adaptive control |
Traffic-dependent modification |
Incompatibility binary |
9 |
88 |
Adaptive control |
Traffic-dependent modification |
Ternary incompatibility |
9 |
89 |
Adaptive control |
Traffic-dependent modification |
Incompatibility max. waiting time |
11 |
61 |
Network control |
EPICS |
Common |
11 |
62 |
Network control |
EPICS |
mppD |
11 |
63 |
Network control |
EPICS |
Signal groups |
11 |
64 |
Network control |
EPICS |
prgD |
11 |
65 |
Network control |
EPICS |
phD |
11 |
66 |
Network control |
EPICS |
phD_sgState |
11 |
67 |
Network control |
EPICS |
phD_param |
11 |
68 |
Network control |
EPICS |
phD_pue |
11 |
69 |
Network control |
EPICS |
pueD |
11 |
70 |
Network control |
EPICS |
pueD_sgEinAus |
11 |
71 |
Network control |
EPICS |
anfD |
11 |
72 |
Network control |
EPICS |
anfD_subQueueOev |
11 |
73 |
Network control |
EPICS |
anfD_subQueueIv |
12 |
74 |
Network control |
Network control module |
Predefined strategy |
12 |
75 |
Network control |
Network control module |
User strategy |
12 |
76 |
Network control |
Network control module |
Predefined traffic stream data |
12 |
77 |
Network control |
Network control module |
Signal group activation |
12 |
78 |
Network control |
Network control module |
Coordination area |
12 |
79 |
Network control |
Network control module |
Restricted area |
12 |
80 |
Network control |
Network control module |
Restricted area (requirement) |
13 |
81 |
Parameters |
vs | plus Phase definition |
Definitions vs | plus phases |
13 |
82 |
Parameters |
vs | plus Phase definition |
Definitions vs | plus phase framework |
14 |
83 |
Topology |
PT sequence |
Definitions PT sequence |
15 |
93 |
On demand control |
On demand parameters |
Error in the switch-off sequence |
15 |
94 |
On demand control |
On demand parameters |
Error in the switch-on sequence |
16 |
96 |
Remaining time display |
Parameters: remaining time display |
Invalid value |
16 |
97 |
Remaining time display |
Parameters: assignment of signal group |
Invalid signal group |
16 |
98 |
Remaining time display |
Parameters Distribution |
Error table |
254 |
253 |
vs | plus |
vs | plus Licensing |
Licence data |