More information on the remaining time display in vs | plus can be found here and in the free expert course in the vs | academy.
Display |
Identifier |
Values |
Description |
|
Number of lamps |
|
Depends on the hardware used. |
|
|
|
|
|
|
31 or 63 |
vs | plus currently supports 31 or 63 lamps. |
|
Max. start delay |
|
This setting allows to delay the start of the remaining time display. |
|
|
|
|
|
|
0 .. 9 |
Start delay in seconds. |
|
Maximum visualizable time |
|
Shows how long the remaining time display runs at maximum during a phase. |
|
|
|
|
|
|
auto |
This is automatically calculated via the number of lamps, the duration of the end sequence, the waiting time per lamp and the maximum start delay. |
|
Ports per signal group |
|
Depends on the number of lamps that are switched. |
|
|
|
|
|
|
5 or 6 |
Either 5 for 31 lamps or 6 for 63 lamps. |
|
End sequence duration |
|
vs | plus will try to count down one lamp per second for the set end sequence duration. |
|
|
|
|
|
|
0 .. 9 |
Allowed values for the end sequence in seconds. |
|
Maximum waiting time per lamp |
|
Specifies the maximum time for which the switching of a lamp may be delayed. |
|
|
|
|
|
|
1 .. 9 |
Waiting time in seconds. |
|
Minimum time |
|
The minimum time specifies the minimum expected remaining time at the start so that the remaining time display is started at all. |
|
|
|
|
|
|
0 .. 9 |
Minimum time in seconds. |
|
HW binary coding |
|
Here it is defined whether the ports are in ascending or descending order for the used control unit. |
|
|
|
|
|
|
descending |
|
|
|
ascending |
|
|
Active program |
|
For which program is the remaining time display activated. |
|
|
|
|
|
|
Checkbox |
Activated |
|
|
List |
All programs |
|
Active Signal group |
|
For which signal groups is there a remaining time display. |
|
|
|
|
|
|
Checkbox |
Activated |
|
|
List |
All signal groups |
|
Display type |
|
Displaying remaining red or remaining green. |
|
|
|
|
|
|
Remaining red |
Currently only remaining red is possible. |
|
First port No. |
|
Port number for communication with the control unit. |
|
|
|
|
|
|
0 .. 3200 |
Port numbers |
Parameter |
from vs | plus version |
Comment |
Remaining time display |
9.0.0 |
Is only included in vs | plus from this version on. |