Function type

Parameter 
read

UBYTE p_DetFunction(WORD DetId);

EN

BYTE p_DetektorFunktion(WORT DetID);

DE

Description

Reads the "Detector function" parameter of the current set.

Version information

from version 6.1.3

Arguments

WORD

DetID

ID number of the desired detector.

Return value

UBYTE

0

INAC

Detektor inaktiv

1

NORM

Standard detector

10

SOFT

Software detector

20

APBPTNC

Parallel pre-announcer without counting with conflicting traffic stream blocking

21

APCPTNC

Parallel pre-indicator without count-in for immediate stage change

25

APBPT

Parallel pre-announcer with counting with conflicting traffic stream blocking

26

APCPT

Parallel pre-indicator with count-in for immediate stage change

27

SCOPT

Serial pre-announcer with counting with conflicting traffic stream blocking

28

ASCPT

Serial pre-indicator with count-in for immediate phase change

30

PCIPTNC

Parallel detector without counting

31

AXCI

Emergency alarm detector

35

PCIPT

Parallel detector with counting

36

SCIPT

Serialised detector with counting

37

-

as AXCI, but via public transport module

40

-

Parallel check out without counting

42

SCOPT

Serial check out with counting

45

PCOPT

Parallel check out with counting

71

REDwJAM

Blockage in the discharge: switch TS to block (red)

72

EXTwJAM

Jam in the discharge: TS no longer extends