The demand control is an extension of the vs | plus idle state. Each partial node can be switched to a demand stage (e.g. main direction dark, secondary direction flashing yellow) after reaching sleep mode. Only when a request is made is vs | plus woken up and resumes normal operation. 


Display

Identifier

Values

Description

Active



vs | plus only allows 8 switch-on definitions and therefore only 8 different switch-on triggers per program. But since you have the possibility to define as many as you like via the flags, you have to define here which of them you want to use. By default, simply the first 8 sequences are marked as active. 







1 .. 8

A maximum of 8 switch-on definitions are permitted. 

Priority

Priority for concurrent occurrences


It may happen that two triggers are detected simultaneously (in the same processing cycle). If you want to prioritize the switch-on sequences accordingly, you can determine the sequence here.







1 .. 9999

1 = highest priority, 9999 = lowest priority.

Trigg. TS

Triggering traffic stream


Shows the traffic stream trigger which initiates the switch-on sequence. In case of a switch-off definition, this column is empty.





DispE.

Display element


Shows the display elements for which the stage of the switch-on or switch-off sequence can be defined. In each case, all display elements of the sub-node, of the display type signal group, are listed.





Seq. x



Here the switch-on or switch-off sequences are defined. For this you must divide your states, which you want to run through sequentially, into a maximum of 5 partial sequences and then define the state and duration for each.







None

No definition



Close

Color image that is defined as a close.



Open

Color image that is defined as open.



Off (Yellow)

Permanent yellow



Off (yellow flashing 1Hz / bright starting)

Yellow flashing 1 Hz bright starting



Off (yellow flashing 1Hz / dark starting)

Yellow flashing 1 Hz starting dark



Off (yellow flashing 2Hz / bright starting)

Yellow flashing 2 Hz bright starting



Off (yellow flashing 2Hz / dark starting)

Yellow flashing 2 Hz starting dark



Off (off)

Dark

Duration x



Duration of the defined sequence x. Is the same for all display elements.







1 .. 3000

Time in seconds. 


Parameter

from vs | plus version

Comment

Control on demand

9.0.0

Is only included in vs | plus as of this version.