Function type

Variables 
write

VOID w_ConfigTsExtension(WORD TsId, UBYTE Value);

EN

LEER m_StatusVSVerlaengerung(WORT VSID, BYTE Wert);

DE

Description

Configures how the traffic stream extensions by vs | plus and user-defined should work. 

For the "Traffic stream extension" functionality, you can set how vs | plus should process this message. It is possible for vs | plus to only pay attention to its own evaluation or to only use the "extension" condition from the free programming. However, it is also possible to logically link both analyses. 

This setting must be set once and can be changed as required.

Version information

from version 6.1.3

Arguments

WORD

TsId

ID number of the desired traffic stream.

UBYTE

Value

0

F_AUS (OFF)

Only the extension evaluation of vs | plus is taken into account.

1

F_EIN (ON)

Only the extension evaluation of the free programming is taken into account.

2

F_UND (AND)

The extension evaluation of the free programming and vs | plus are linked with AND.

3

F_ODER (OR)

The extension evaluation of the free programming and vs | plus are linked by OR.

Return value

None

Remark

Not applicable for public transport traffic streams.