13

fatal error

Supply with VCB

The VCB file is corrupt. File check failed!

1

Error code: 

2 - The intersection number does not match  

3 - Signal groups are addressed that do not exist on the controller  

4 - Detectors are addressed that do not exist on the controller 

5 - The file could not be opened 

6 - It is not a 'VCB ́ file 

7 - File version does not match vs | plus version

8 - Error in parameter file 

9 - Errors in the data structure 

10 - Error in parameter set 

11 - Invalid parameter values 

99 - Global data structure does not exist 

2

Error code 1 is

Message parameter 2

2, 3, 4, 7

Expected value

6

0: VCB file

1: Multi-VCB file

9

vs | plus group number

11

Read value

3

Error code 1 is

Message parameter 3

2, 4, 7

Read value

6

1: surplus vs | plus supply

2: surplus open vs | plus supply

3: Multi-VCB not detected

9

vs | plus object number

11

Hi-word parameter ID

4

Error code 1 is

Message parameter 4

7

0: wrong vs | plus version

1: wrong open vs | plus version

9

Error detail (*)

10

Program number

11

Lo-word parameter ID


(*) Error detail Number

Meaning

1

Invalid symbol / character

2

Invalid value

4

Invalid number of items

8

ID in the invalid range

16

Untreated traffic stream conflict

32

check rows, columns


The assignment of the vs  | plus group and object numbers can be found in the table  vs | plus group and object numbers.